Lab/Sensor atlas
80 entries · 12 families

Every way to feel a room.

Choose on physics: what is measured, over what range, at what resolution, with what accuracy and how fast. Specs are typical for the class of device, not a promise for a specific module. No model numbers, no prices.

80 shown

Temperature

6 entries

Contact and non-contact heat measurement, from ambient rooms to kilns and bearings.

Principle Range Resolution Accuracy Response Interface Notes
Precision digital temperature
Ambient and surface temperature via a band-gap sensing element.
−40 to +125 °C 0.0078 °C ±0.2 °C (0–65 °C) 1 Hz, τ ≈ 5 s in still air I²C or SPI
Best general-purpose room and equipment sensor. Keep it away from regulators and power resistors; self-heating shows up as a fixed offset.
Platinum RTD (PT100 / PT1000)
Temperature from the resistance of a platinum element; the lab standard for ducts and machines.
−200 to +600 °C 0.01 °C with a 24-bit ADC ±0.1 °C class A 1–10 Hz, τ 5–30 s in a thermowell 2/3/4-wire + ADC
Four-wire measurement removes lead resistance. Linearise, and expect a slow but very stable reading.
Thermocouple front end
Temperature from the microvolt Seebeck voltage at a junction of two dissimilar metals.
−200 to +1372 °C (type K) 0.25 °C ±1.5 °C or ±0.4 % 4–20 Hz, τ 0.1–5 s bare junction SPI/analog + cold-junction sensor
Covers ovens, exhausts and kilns that would destroy a semiconductor sensor. Cold-junction compensation is mandatory; use twisted, shielded, grounded-at-one-end leads.
NTC thermistor
Temperature as a falling resistance; the fast, cheap workhorse.
−50 to +150 °C ≈0.05 °C near room temperature ±0.5 °C <1 s in a bead Analog divider + ADC
Strongly non-linear; convert with Steinhart–Hart and calibrate at two points. Excellent for fast air and surface changes.
Infrared thermometer
Surface temperature from emitted infrared, without touching the target.
−70 to +380 °C 0.02 °C ±0.5 °C 2–10 Hz I²C
Use on moving parts, busbars and hot spots. Emissivity and field-of-view dominate the error: a shiny busbar reads far too low without correction.
Thermal camera array
A low-resolution heat image: 32×24 pixels of temperature.
−40 to +300 °C 0.1 °C, 0.1 °C NETD ±1 °C 4–8 Hz I²C
Perfect for mapping rack hot spots and finding a warm breaker before it fails. Low spatial resolution: treat each pixel as a zone, not a point.

Humidity & moisture

6 entries

Water in the air, in soil, on the floor, and the dew point where it condenses.

Principle Range Resolution Accuracy Response Interface Notes
Capacitive relative humidity
Water vapour in air from the capacitance of a polymer layer.
0–100 %RH 0.04 %RH ±2 %RH 1 Hz, τ 8 s I²C
Recovers well after condensation but should not sit in liquid water. Avoid permanent exposure to solvents and strong acids.
Resistive humidity
Humidity from the resistance of a hygroscopic layer.
20–90 %RH 0.1 %RH ±5 %RH Slow, τ 1–2 min Analog
Cheap and adequate for comfort trends. It drifts and should not be used for a control loop or a compliance record.
Capacitive soil moisture
Volumetric water content of soil or a growing medium.
0–100 % VWC (after calibration) 0.1 % ±3 % with a local calibration 1 Hz Analog
Capacitive probes resist corrosion far better than resistive types. Calibrate dry and saturated in the actual medium; the raw number is not a percentage until you do.
Conductivity flood probe
The presence and depth of standing water at a low point.
Binary + wet gradient Probe pitch, typically 1–5 mm Detection only <1 s Digital input or analog
Put it where water actually collects: drip trays, under raised floors, sump lips. AC excitation or gold-plated electrodes prevent electrolysis from eating the probe.
Water leak rope
Water contact anywhere along a continuous cable run.
Up to tens of metres, zoned Per zone Detection only <5 s Digital zone inputs
Ideal under floors, along cable trays and around chilled-water pipework. Zoned rope tells you where the water is, not just that there is water.
Dew-point / condensation
The temperature at which air reaches saturation, or a mirror that fogs.
−20 to +80 °C dew point 0.1 °C ±0.5 °C 1–60 s depending on principle I²C / calculated from T and RH
Derive it from a good temperature and humidity pair, or use a chilled mirror where the result is a control or compliance value. It is the number that predicts condensation on a cold pipe.

Pressure & flow

6 entries

Barometric, differential and liquid pressure, plus the flow that proves it is moving.

Principle Range Resolution Accuracy Response Interface Notes
Barometric pressure
Absolute atmospheric pressure, altitude and slow weather trend.
300–1100 hPa 0.016 hPa ±0.12 hPa 1–25 Hz I²C or SPI
Also catches fast transients: a door slam, a fan start, a duct collapsing. Compare against a second sensor before believing a spike.
Differential pressure
The pressure difference between two points: across a filter, a door or a duct.
±500 Pa to ±1 kPa 0.1 Pa ±1 % FS 1–10 Hz I²C / analog
Use a restrictor or averaging pitot to tame turbulent duct readings. Route both ports away from fans and sharp bends.
Liquid pressure transducer
Pressure in a pipe or vessel, from a strain-gauge or capacitive diaphragm.
0–1.2 MPa (0–12 bar) 0.1 % FS ±0.5 % FS 1 kHz 4–20 mA or 0–5 V
Fit a snubber against water hammer and isolate the sensor behind a gauge valve. Check the wetted material against the fluid.
Turbine / paddle flow
Liquid flow from the pulse rate of a spinning rotor.
1–30 L/min ≈0.1 L totalised ±3 % Up to 100 Hz Pulse / interrupt
Clean water only; grit wears the rotor. A flow switch proves movement; a turbine proves volume. Use the right one.
Clamp-on ultrasonic flow
Flow from the transit-time difference of sound across a pipe.
0–5 m/s 0.01 m/s ±1 % with a good pipe run 1 Hz UART
Non-invasive, so nothing touches the fluid. It needs a straight run, a known pipe wall and couplant. A bad installation reads plausibly and wrongly.
Air speed
Wind or duct velocity from cups, a vane or a heated element.
0–30 m/s (hot-wire 0–20 m/s) 0.1 m/s ±3 % 1 Hz Pulse or analog
Hot-wire types are accurate at low speed but dislike dust. In a duct, measure at an averaging point, not against the wall.

Gas & air quality

12 entries

Combustible gas, CO, CO₂, solvents, refrigerants, oxygen and toxic gases.

Principle Range Resolution Accuracy Response Interface Notes
NDIR carbon dioxide
CO₂ concentration from absorption of a specific infrared wavelength.
0–5000 ppm 1 ppm ±(30 ppm + 3 % of reading) 1–2 s I²C or UART
The right sensor for occupancy and ventilation. Automatic baseline correction assumes the room sees fresh air; in a sealed plant room it will drift unless you calibrate.
Electrochemical carbon monoxide
CO concentration from a small current produced by oxidation at an electrode.
0–1000 ppm 0.1 ppm ±2 % FS t90 ≈ 30 s Analog or UART
Boiler rooms, garages, generator intakes. Sensible to cross-sensitivity to hydrogen. Sensor life is typically 2–5 years; log the install date.
Catalytic combustible gas
Explosive gas as a percentage of the lower explosive limit, by burning it on a bead.
0–100 % LEL 0.1 % LEL ±3 % LEL t90 10–30 s Analog
Methane, LPG and propane. Requires oxygen to work, and silicone or lead vapour poisons the bead. Recalibrate with a known gas, or the alarm is theatre.
Semiconductor VOC / air quality
A broad change in reducing gases from a heated metal-oxide surface.
10–1000 ppm equivalent Qualitative trend ±20 %, heavy cross-sensitivity τ 10 s Analog
A useful trend and a poor instrument. Temperature and humidity move the reading. Use it to trigger a second, selective sensor.
Photoionisation VOC
Total volatile organic compounds from ions created by a UV lamp.
0–1000 ppm 10 ppb ±2 % 1 s UART or analog
Solvent stores, labs and paint booths. The lamp needs cleaning and eventual replacement, and the response depends on the ionisation energy of each compound.
Electrochemical ozone
Ozone concentration from an electrochemical cell.
0–1000 ppb 1 ppb ±2 % t90 ≈ 30 s Analog
Near UV lamps, laser printers, welding and water treatment. Ozone is a strong irritant at low concentration, so the alarm threshold is low.
Electrochemical hydrogen sulfide
H₂S from an electrochemical cell.
0–100 ppm 0.1 ppm ±2 % t90 ≈ 30 s Analog
Sewers, sumps and pulp. At high concentration the cell can be poisoned, and the sense of smell is gone long before the danger.
Electrochemical ammonia
Ammonia concentration from an electrochemical cell.
0–100 ppm 0.1 ppm ±2 % t90 30–60 s Analog
Refrigeration plant, cold rooms and livestock buildings. Ammonia is lighter than air, so headspace placement matters.
Electrochemical oxygen
Oxygen fraction, including the drop caused by inert gas or displacement.
0–25 % 0.1 % ±0.5 % t90 ≈ 15 s Analog or UART
Confined spaces, nitrogen rooms and battery rooms. A low-oxygen alarm is a life-safety function: test it with a known gas, not by breathing on it.
Electrochemical hydrogen
Hydrogen from battery off-gassing or a leak.
0–1000 ppm 1 ppm ±2 % t90 ≈ 30 s Analog
Battery rooms and charging bays. Hydrogen is buoyant: sample the ceiling void and the top of the rack, not the floor.
Refrigerant leak
Refrigerant concentration by infrared absorption, tuned to the blend.
0–2000 ppm 1 ppm ±5 % 5 s UART
Plant rooms and cold rooms. The sensor is blend-specific; confirm what the system actually contains before ordering the element.
Radon
Radon activity from ionisation in a chamber.
0–1000 Bq/m³ 1 Bq/m³ ±20 % Hours (long averaging) UART
Basements and ground floors. Radon is a long-term average problem, so a fast spike is noise; average over days and ventilate on the trend.

Smoke & particulates

4 entries

Photoelectric and ionisation smoke, laser particulate counting and dust.

Principle Range Resolution Accuracy Response Interface Notes
Photoelectric smoke
Smoke from light scattered by particles in a chamber.
0–20 %/m obscuration 0.1 %/m Alarm at 3–5 %/m 5–15 s Digital alarm or analog
The best general choice: responds to smouldering fires and visible smoke. Dust, steam and insects cause false alarms, so keep it out of kitchens and plant rooms with dirty air.
Ionisation smoke
Smoke by the change in current through an ionised air chamber.
Alarm threshold in %/m equivalent Alarm point Detects fast flaming fires early <5 s Digital alarm
Contains a radioactive source, so disposal and transport are regulated. Very fast on flaming fires, more prone to false alarms from cooking and dust.
Laser particulate counter
PM1, PM2.5 and PM10 mass concentration by laser scattering.
0–1000 µg/m³ 1 µg/m³ ±10 % 1 s UART or I²C
For ventilation checks and workshop dust, not for fire detection. Fan and inlet orientation decide whether the number means anything.
Optical dust
Airborne dust mass by infrared scattering.
0–1 mg/m³ 0.001 mg/m³ ±15 % 1 s Analog or UART
Extraction hoods, sawdust and grain. Clean the optical window on a schedule or the reading falls as the dust builds.

Light & radiation

6 entries

Lux, UV, colour, flame, infrared beams and ionising radiation.

Principle Range Resolution Accuracy Response Interface Notes
Ambient light (lux)
Illuminance as the human eye responds to it.
0.01–100 000 lx 0.01 lx ±5 % 10 Hz I²C
Lighting control, display dimming and daylight harvesting. Put it behind a diffuser and match its spectral response to the job.
UV index
UVA and UVB irradiance, reported as a UV index.
0–15 UVI 0.1 UVI ±5 % 1 Hz I²C or analog
Welding booths, UV cure stations and outdoor exposure. Quartz covers and ageing change the calibration.
Photodiode / photoresistor
Fast relative light level; the basis of beam-break and tachometry.
400–1100 nm Relative, µs edges ±10 % relative Microseconds Analog + comparator
Use a comparator and hysteresis for a clean beam-break edge. A photoresistor is slower and drifts; a photodiode is the industrial choice.
RGB colour
Colour and intensity in filtered channels.
16-bit per channel 16-bit ±2 % 10 Hz I²C
Sorting, liquid colour and label verification. The illuminant matters more than the sensor: fix the light source before trusting a colour decision.
Ionising radiation (Geiger–Müller)
Ionising radiation events as countable pulses.
0–10 mSv/h 1 count ±15 % Seconds to average Pulse / interrupt
Scrap-metal monitoring, NDT sources and educational labs. Count with an interrupt, not polling, or you lose events.
Infrared flame detector
The flicker signature of a flame in the near infrared.
760–1100 nm Alarm point Detection within 3 s <3 s Digital or analog
Fast, but sunlight and halogen lamps can fool it. Pair it with smoke detection and require both before a suppression action.

Position & presence

14 entries

Distance, presence, orientation, rotation, magnetic fields and motion.

Principle Range Resolution Accuracy Response Interface Notes
Passive infrared motion
Movement of warm bodies across a segmented infrared field of view.
3–7 m, 120° cone Zone-based Detection only ≈1 s Digital
Fine for 'did someone move', poor for 'is someone still here'. Warm air currents, sunlight and pets cause false triggers.
24 GHz mmWave presence
Presence and micro-movement from reflected radar, including breathing.
0.1–8 m Millimetre displacement ±0.1 m ranging 0.1 s UART
Detects a still person where PIR fails. It sees through plastic and plasterboard, but not metal. Tune the gate and sensitivity for the room.
Ultrasonic distance
Distance from the time of flight of a sound pulse.
2 cm–4 m 3 mm ±1 % 20–50 Hz Trigger/echo or I²C
Tanks, bins, sumps and robot bumpers. The speed of sound changes with temperature, so compensate or accept a slow drift.
Time-of-flight laser
Distance from the flight time of a modulated light pulse.
4–8 m 1 mm ±1 % Up to 60 Hz I²C
Precise level and position. Glass, black rubber and very shiny surfaces return poor echoes; test the actual target.
Infrared proximity
Short-range presence from reflected infrared.
2–150 cm 1 cm ±10 % 100 Hz I²C
Cheap and fast for hand detection and bin fill. Ambient sunlight is the enemy; choose a modulated type with ambient rejection.
Reed / magnetic contact
Open or closed state of a door, gate, lid or panel.
Binary State Contact rating dependent <1 ms Digital, normally-closed preferred
Wire normally-closed so a cut cable looks like an alarm, not a safe door. Add a second contact for tamper.
Hall magnetic field
Magnetic flux density: position, rotation or current indirectly.
±300 mT 12-bit ±1 % 1 kHz Analog or I²C
Non-contact RPM, end-stops and magnet position. Keep the magnet gap inside the specified window and expect temperature drift.
Tilt / ball switch
Orientation past a fixed angle, or a lid being lifted.
Typical 10–45° trip Binary Angle tolerance ±5° <10 ms Digital
Tip-over protection, lid tamper and float. Debounce mechanically; a ball switch chatters at the threshold.
3-axis accelerometer
Acceleration, vibration and shock on three axes.
±2 to ±16 g 0.06 mg/LSB at ±2 g ±1 % 1 kHz+ I²C or SPI
A machine-health front end when sampled fast and analysed in the frequency domain. For bearing faults, mount it rigidly on the housing, not on a bracket.
3-axis gyroscope
Angular rate around three axes.
±125 to ±2000 °/s 0.007 °/s ±2 % 1 kHz SPI or I²C
Rotation, steering and motion compensation. It drifts; fuse it with an accelerometer or magnetometer for a stable angle.
3-axis magnetometer
The local magnetic field: compass heading, vehicle presence or tamper.
±1300 µT 0.3 µT ±1° after calibration 100 Hz I²C
Calibrate hard and soft iron offsets in place. Steel structures and motors distort the field far more than you expect.
Quadrature rotary encoder
Rotation angle and direction from two phase-shifted pulses.
20–1024 counts/revolution 0.09° mechanical Count-exact Up to 100 kHz edges Interrupts / quadrature decoder
The correct knob for a control panel: endless, detented and readable. Debounce in hardware and decode in an interrupt.
Dual-axis joystick
X/Y position from two potentiometers or Hall sensors.
±30° travel 10-bit ±1 % 100 Hz Analog
Camera control, manual jog and menus. Add a centre dead-zone and a spring-return check at boot.
Linear potentiometer / fader
Linear position as a voltage divider.
10 kΩ, 10–100 mm travel 0.1 mm ±2 % Analog, 100 Hz Analog
Faders, damper position and manual setpoints. Wear at the wiper shows up as noise; filter and replace on schedule.

Force & vibration

5 entries

Weight, strain, impact and the vibration signature of a machine that is wearing out.

Principle Range Resolution Accuracy Response Interface Notes
Load cell + 24-bit ADC
Weight or force from a strain-gauge bridge.
0–50 kg (cell dependent) 0.1 g ±0.02 % FS 10–80 Hz Bridge + 24-bit ADC
Tanks, parts counting, door weight and feed hoppers. Mount so load passes through the cell axis; side load is the usual cause of drift.
Strain gauge
Microstrain in a structure or machine frame.
±2000 µε 1 µε ±1 % 1 kHz Bridge + 24-bit ADC
Structural monitoring and overload detection. Temperature compensation and a stable bridge excitation matter more than ADC bits.
Force-sensitive resistor
Contact force from a change in resistance.
0.1–10 N Logarithmic ±10 % 100 Hz Analog
Touch, seat occupancy and grip. Repeatability is poor; use it for presence of force, not for measurement.
Piezo vibration / shock
Vibration and impact from a piezoelectric element.
0.1–10 kHz Relative ±10 % relative Microseconds Analog + threshold
Impact detection and bearing knock. The signal is high-impedance: buffer it close to the sensor and clamp the input.
Capacitive touch
A finger or hand near an electrode.
0–10 mm through glass or plastic 8-bit proximity ±1 mm with tuning 50 Hz Digital
Sealed panels with no moving parts. A film of water can look like a touch, so guard-ring the electrode and require a deliberate gesture.

Electrical

7 entries

Current, voltage, energy, contactor feedback and battery state.

Principle Range Resolution Accuracy Response Interface Notes
Current transformer clamp
AC current in a conductor from the induced secondary current.
0–100 A AC 0.1 A ±1 % 50/60 Hz cycles Analog (burden resistor)
Split-core clamps retrofit without cutting the cable. Clamp one conductor only; clamping the whole cable reads zero.
Hall current sensor
DC or AC current from the magnetic field around a conductor.
±30 A 10 mA ±1 % 100 kHz Analog
Solar strings, batteries and DC pumps. Zero-offset drift is the main error; take a no-load reading at boot.
Isolated voltage sense
Mains or DC bus presence and magnitude.
0–250 V AC/DC 0.1 V ±1 % 1 kHz Isolated analog
Mains-present, generator and UPS status. Isolation is not optional: use a certified divider or transformer, never a bare resistor chain.
Energy / power meter
Active power and cumulative energy per circuit.
0–100 A 0.1 % active energy ±0.5 % 1 Hz SPI or UART
Allocates kWh to circuits and proves savings. Calibrate the voltage and current channels against a reference meter.
Contactor feedback
Whether a relay or contactor actually closed, not just whether it was commanded.
Binary State Contact dependent <10 ms Digital, opto-isolated
The difference between a command and a fact. Use an auxiliary contact and alarm when the two disagree for more than a second.
UPS dry contact
On-battery, low-battery and fault state from a UPS.
Binary set State Per UPS <100 ms Opto-isolated digital
Treat as an input, never as a source of truth for runtime. The UPS may lie about charge; measure the load and the battery separately.
Battery voltage / current
Terminal voltage and charge/discharge current of a battery bank.
0–60 V, ±50 A 1 mV, 10 mA ±0.5 % 10 Hz I²C
12/24/48 V banks and solar. Voltage alone is a poor state-of-charge estimate under load; count coulombs as well.

Level & proximity

5 entries

Tank level, float state, and industrial proximity and beam detection.

Principle Range Resolution Accuracy Response Interface Notes
Float switch
A liquid reaching a fixed height.
Binary Float travel ±5 mm <100 ms Digital
Use two: one to start and stop the pump, one as an independent overflow alarm. Never rely on a single float for a safety function.
Capacitive proximity
Non-metallic objects or liquid through a wall.
1–25 mm Binary ±10 % 100 Hz Digital
Detects product through a plastic tank wall. Humidity and build-up shift the threshold; teach it with the tank empty and full.
Inductive proximity
Metal objects without contact.
2–15 mm Binary ±5 % 1 kHz Digital
End-stops, RPM and metal part counting. The sensing distance is quoted for mild steel; aluminium and stainless need a correction factor.
Photoelectric beam
An object interrupting a light beam over a long distance.
0.1–30 m Beam width Detection only <1 ms Digital
Perimeter, conveyor counting and safety curtains. Align it, shade it from sunlight, and add a test input so a broken beam fails safe.
Radar level
Liquid or solid level from the flight time of a radar pulse.
0.1–15 m 1 mm ±2 mm 1 Hz UART
Tanks with foam, vapour or dust. It struggles with low-dielectric media; check the dielectric constant before promising accuracy.

Identity & biometric

5 entries

RFID, keys, keypads, fingerprints and vital-sign front ends.

Principle Range Resolution Accuracy Response Interface Notes
RFID / NFC reader
A tag identity and, where supported, a secure memory sector.
4–10 cm Tag UID Read reliability >99 % ≈100 ms SPI / UART
Access, tool tracking and consumable spools. A UID is an identifier, not a secret; use authenticated sectors for access decisions.
Fingerprint
A fingerprint image reduced to a template.
500 dpi Template match FAR ≈0.1 % <1 s UART
Store templates, never images. Add a PIN or card as a second factor for anything that matters.
Matrix / capacitive keypad
Key presses on a 12- or 16-key pad.
12–16 keys Key event With debounce 50 Hz Digital matrix
PIN entry and setpoints. Scan with a matrix and debounce; a capacitive pad needs a deliberate-press rule to reject water films.
PPG heart rate / SpO₂
Pulse and blood-oxygen estimate from light absorption.
30–240 bpm 1 bpm ±2 bpm 25 Hz I²C
Presence and wellness, not diagnosis. Motion and ambient light destroy the signal; shield the sensor and reject bad frames.
Single-lead ECG front end
The electrical activity of the heart.
0.5–40 Hz 24-bit Diagnostic-grade front end 250 Hz Analog + ADC
Requires proper electrode placement, isolation and a medical-grade supply. This is a demonstration front end, not a medical device.

Weather

4 entries

Rain, wind, solar irradiance and lightning near the site.

Principle Range Resolution Accuracy Response Interface Notes
Tipping-bucket rain gauge
Rainfall from counted bucket tips.
0.2 mm per tip 0.2 mm ±2 % Per tip Pulse / interrupt
Skip irrigation after real rain and watch roof drainage. Debounce the reed; wind makes it chatter.
Wind vane
Wind direction from a coded vane.
0–360°, 16 points 1° ±5° 1 Hz Analog or Gray code
Combine with an anemometer for a wind vector. Mount it clear of the roof edge or it measures the building, not the wind.
Lightning detector
The radio signature of lightning and its approximate distance.
1–40 km ≈1 km ±20 % Event I²C
Storm shutdown for outdoor equipment and irrigation. Treat distance as an estimate and add a margin.
Solar irradiance
Broadband solar power per square metre.
0–1500 W/m² 1 W/m² ±5 % 1 Hz Analog
Solar yield, greenhouse shading and irrigation demand. Keep the dome clean; a dirty dome silently reads low.

How these become a system

A sensor is one input to a loop: condition the signal, decide with a rule you can read, act through a relay or a display, then keep a record. The job sheets show the loop for twelve real problems.