Every way to feel a room.
Choose on physics: what is measured, over what range, at what resolution, with what accuracy and how fast. Specs are typical for the class of device, not a promise for a specific module. No model numbers, no prices.
Temperature
6 entriesContact and non-contact heat measurement, from ambient rooms to kilns and bearings.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Precision digital temperature
Ambient and surface temperature via a band-gap sensing element.
|
−40 to +125 °C | 0.0078 °C | ±0.2 °C (0–65 °C) | 1 Hz, τ ≈ 5 s in still air | I²C or SPI | Best general-purpose room and equipment sensor. Keep it away from regulators and power resistors; self-heating shows up as a fixed offset. |
|
Platinum RTD (PT100 / PT1000)
Temperature from the resistance of a platinum element; the lab standard for ducts and machines.
|
−200 to +600 °C | 0.01 °C with a 24-bit ADC | ±0.1 °C class A | 1–10 Hz, τ 5–30 s in a thermowell | 2/3/4-wire + ADC | Four-wire measurement removes lead resistance. Linearise, and expect a slow but very stable reading. |
|
Thermocouple front end
Temperature from the microvolt Seebeck voltage at a junction of two dissimilar metals.
|
−200 to +1372 °C (type K) | 0.25 °C | ±1.5 °C or ±0.4 % | 4–20 Hz, τ 0.1–5 s bare junction | SPI/analog + cold-junction sensor | Covers ovens, exhausts and kilns that would destroy a semiconductor sensor. Cold-junction compensation is mandatory; use twisted, shielded, grounded-at-one-end leads. |
|
NTC thermistor
Temperature as a falling resistance; the fast, cheap workhorse.
|
−50 to +150 °C | ≈0.05 °C near room temperature | ±0.5 °C | <1 s in a bead | Analog divider + ADC | Strongly non-linear; convert with Steinhart–Hart and calibrate at two points. Excellent for fast air and surface changes. |
|
Infrared thermometer
Surface temperature from emitted infrared, without touching the target.
|
−70 to +380 °C | 0.02 °C | ±0.5 °C | 2–10 Hz | I²C | Use on moving parts, busbars and hot spots. Emissivity and field-of-view dominate the error: a shiny busbar reads far too low without correction. |
|
Thermal camera array
A low-resolution heat image: 32×24 pixels of temperature.
|
−40 to +300 °C | 0.1 °C, 0.1 °C NETD | ±1 °C | 4–8 Hz | I²C | Perfect for mapping rack hot spots and finding a warm breaker before it fails. Low spatial resolution: treat each pixel as a zone, not a point. |
Humidity & moisture
6 entriesWater in the air, in soil, on the floor, and the dew point where it condenses.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Capacitive relative humidity
Water vapour in air from the capacitance of a polymer layer.
|
0–100 %RH | 0.04 %RH | ±2 %RH | 1 Hz, τ 8 s | I²C | Recovers well after condensation but should not sit in liquid water. Avoid permanent exposure to solvents and strong acids. |
|
Resistive humidity
Humidity from the resistance of a hygroscopic layer.
|
20–90 %RH | 0.1 %RH | ±5 %RH | Slow, τ 1–2 min | Analog | Cheap and adequate for comfort trends. It drifts and should not be used for a control loop or a compliance record. |
|
Capacitive soil moisture
Volumetric water content of soil or a growing medium.
|
0–100 % VWC (after calibration) | 0.1 % | ±3 % with a local calibration | 1 Hz | Analog | Capacitive probes resist corrosion far better than resistive types. Calibrate dry and saturated in the actual medium; the raw number is not a percentage until you do. |
|
Conductivity flood probe
The presence and depth of standing water at a low point.
|
Binary + wet gradient | Probe pitch, typically 1–5 mm | Detection only | <1 s | Digital input or analog | Put it where water actually collects: drip trays, under raised floors, sump lips. AC excitation or gold-plated electrodes prevent electrolysis from eating the probe. |
|
Water leak rope
Water contact anywhere along a continuous cable run.
|
Up to tens of metres, zoned | Per zone | Detection only | <5 s | Digital zone inputs | Ideal under floors, along cable trays and around chilled-water pipework. Zoned rope tells you where the water is, not just that there is water. |
|
Dew-point / condensation
The temperature at which air reaches saturation, or a mirror that fogs.
|
−20 to +80 °C dew point | 0.1 °C | ±0.5 °C | 1–60 s depending on principle | I²C / calculated from T and RH | Derive it from a good temperature and humidity pair, or use a chilled mirror where the result is a control or compliance value. It is the number that predicts condensation on a cold pipe. |
Pressure & flow
6 entriesBarometric, differential and liquid pressure, plus the flow that proves it is moving.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Barometric pressure
Absolute atmospheric pressure, altitude and slow weather trend.
|
300–1100 hPa | 0.016 hPa | ±0.12 hPa | 1–25 Hz | I²C or SPI | Also catches fast transients: a door slam, a fan start, a duct collapsing. Compare against a second sensor before believing a spike. |
|
Differential pressure
The pressure difference between two points: across a filter, a door or a duct.
|
±500 Pa to ±1 kPa | 0.1 Pa | ±1 % FS | 1–10 Hz | I²C / analog | Use a restrictor or averaging pitot to tame turbulent duct readings. Route both ports away from fans and sharp bends. |
|
Liquid pressure transducer
Pressure in a pipe or vessel, from a strain-gauge or capacitive diaphragm.
|
0–1.2 MPa (0–12 bar) | 0.1 % FS | ±0.5 % FS | 1 kHz | 4–20 mA or 0–5 V | Fit a snubber against water hammer and isolate the sensor behind a gauge valve. Check the wetted material against the fluid. |
|
Turbine / paddle flow
Liquid flow from the pulse rate of a spinning rotor.
|
1–30 L/min | ≈0.1 L totalised | ±3 % | Up to 100 Hz | Pulse / interrupt | Clean water only; grit wears the rotor. A flow switch proves movement; a turbine proves volume. Use the right one. |
|
Clamp-on ultrasonic flow
Flow from the transit-time difference of sound across a pipe.
|
0–5 m/s | 0.01 m/s | ±1 % with a good pipe run | 1 Hz | UART | Non-invasive, so nothing touches the fluid. It needs a straight run, a known pipe wall and couplant. A bad installation reads plausibly and wrongly. |
|
Air speed
Wind or duct velocity from cups, a vane or a heated element.
|
0–30 m/s (hot-wire 0–20 m/s) | 0.1 m/s | ±3 % | 1 Hz | Pulse or analog | Hot-wire types are accurate at low speed but dislike dust. In a duct, measure at an averaging point, not against the wall. |
Gas & air quality
12 entriesCombustible gas, CO, CO₂, solvents, refrigerants, oxygen and toxic gases.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
NDIR carbon dioxide
CO₂ concentration from absorption of a specific infrared wavelength.
|
0–5000 ppm | 1 ppm | ±(30 ppm + 3 % of reading) | 1–2 s | I²C or UART | The right sensor for occupancy and ventilation. Automatic baseline correction assumes the room sees fresh air; in a sealed plant room it will drift unless you calibrate. |
|
Electrochemical carbon monoxide
CO concentration from a small current produced by oxidation at an electrode.
|
0–1000 ppm | 0.1 ppm | ±2 % FS | t90 ≈ 30 s | Analog or UART | Boiler rooms, garages, generator intakes. Sensible to cross-sensitivity to hydrogen. Sensor life is typically 2–5 years; log the install date. |
|
Catalytic combustible gas
Explosive gas as a percentage of the lower explosive limit, by burning it on a bead.
|
0–100 % LEL | 0.1 % LEL | ±3 % LEL | t90 10–30 s | Analog | Methane, LPG and propane. Requires oxygen to work, and silicone or lead vapour poisons the bead. Recalibrate with a known gas, or the alarm is theatre. |
|
Semiconductor VOC / air quality
A broad change in reducing gases from a heated metal-oxide surface.
|
10–1000 ppm equivalent | Qualitative trend | ±20 %, heavy cross-sensitivity | τ 10 s | Analog | A useful trend and a poor instrument. Temperature and humidity move the reading. Use it to trigger a second, selective sensor. |
|
Photoionisation VOC
Total volatile organic compounds from ions created by a UV lamp.
|
0–1000 ppm | 10 ppb | ±2 % | 1 s | UART or analog | Solvent stores, labs and paint booths. The lamp needs cleaning and eventual replacement, and the response depends on the ionisation energy of each compound. |
|
Electrochemical ozone
Ozone concentration from an electrochemical cell.
|
0–1000 ppb | 1 ppb | ±2 % | t90 ≈ 30 s | Analog | Near UV lamps, laser printers, welding and water treatment. Ozone is a strong irritant at low concentration, so the alarm threshold is low. |
|
Electrochemical hydrogen sulfide
H₂S from an electrochemical cell.
|
0–100 ppm | 0.1 ppm | ±2 % | t90 ≈ 30 s | Analog | Sewers, sumps and pulp. At high concentration the cell can be poisoned, and the sense of smell is gone long before the danger. |
|
Electrochemical ammonia
Ammonia concentration from an electrochemical cell.
|
0–100 ppm | 0.1 ppm | ±2 % | t90 30–60 s | Analog | Refrigeration plant, cold rooms and livestock buildings. Ammonia is lighter than air, so headspace placement matters. |
|
Electrochemical oxygen
Oxygen fraction, including the drop caused by inert gas or displacement.
|
0–25 % | 0.1 % | ±0.5 % | t90 ≈ 15 s | Analog or UART | Confined spaces, nitrogen rooms and battery rooms. A low-oxygen alarm is a life-safety function: test it with a known gas, not by breathing on it. |
|
Electrochemical hydrogen
Hydrogen from battery off-gassing or a leak.
|
0–1000 ppm | 1 ppm | ±2 % | t90 ≈ 30 s | Analog | Battery rooms and charging bays. Hydrogen is buoyant: sample the ceiling void and the top of the rack, not the floor. |
|
Refrigerant leak
Refrigerant concentration by infrared absorption, tuned to the blend.
|
0–2000 ppm | 1 ppm | ±5 % | 5 s | UART | Plant rooms and cold rooms. The sensor is blend-specific; confirm what the system actually contains before ordering the element. |
|
Radon
Radon activity from ionisation in a chamber.
|
0–1000 Bq/m³ | 1 Bq/m³ | ±20 % | Hours (long averaging) | UART | Basements and ground floors. Radon is a long-term average problem, so a fast spike is noise; average over days and ventilate on the trend. |
Smoke & particulates
4 entriesPhotoelectric and ionisation smoke, laser particulate counting and dust.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Photoelectric smoke
Smoke from light scattered by particles in a chamber.
|
0–20 %/m obscuration | 0.1 %/m | Alarm at 3–5 %/m | 5–15 s | Digital alarm or analog | The best general choice: responds to smouldering fires and visible smoke. Dust, steam and insects cause false alarms, so keep it out of kitchens and plant rooms with dirty air. |
|
Ionisation smoke
Smoke by the change in current through an ionised air chamber.
|
Alarm threshold in %/m equivalent | Alarm point | Detects fast flaming fires early | <5 s | Digital alarm | Contains a radioactive source, so disposal and transport are regulated. Very fast on flaming fires, more prone to false alarms from cooking and dust. |
|
Laser particulate counter
PM1, PM2.5 and PM10 mass concentration by laser scattering.
|
0–1000 µg/m³ | 1 µg/m³ | ±10 % | 1 s | UART or I²C | For ventilation checks and workshop dust, not for fire detection. Fan and inlet orientation decide whether the number means anything. |
|
Optical dust
Airborne dust mass by infrared scattering.
|
0–1 mg/m³ | 0.001 mg/m³ | ±15 % | 1 s | Analog or UART | Extraction hoods, sawdust and grain. Clean the optical window on a schedule or the reading falls as the dust builds. |
Light & radiation
6 entriesLux, UV, colour, flame, infrared beams and ionising radiation.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Ambient light (lux)
Illuminance as the human eye responds to it.
|
0.01–100 000 lx | 0.01 lx | ±5 % | 10 Hz | I²C | Lighting control, display dimming and daylight harvesting. Put it behind a diffuser and match its spectral response to the job. |
|
UV index
UVA and UVB irradiance, reported as a UV index.
|
0–15 UVI | 0.1 UVI | ±5 % | 1 Hz | I²C or analog | Welding booths, UV cure stations and outdoor exposure. Quartz covers and ageing change the calibration. |
|
Photodiode / photoresistor
Fast relative light level; the basis of beam-break and tachometry.
|
400–1100 nm | Relative, µs edges | ±10 % relative | Microseconds | Analog + comparator | Use a comparator and hysteresis for a clean beam-break edge. A photoresistor is slower and drifts; a photodiode is the industrial choice. |
|
RGB colour
Colour and intensity in filtered channels.
|
16-bit per channel | 16-bit | ±2 % | 10 Hz | I²C | Sorting, liquid colour and label verification. The illuminant matters more than the sensor: fix the light source before trusting a colour decision. |
|
Ionising radiation (Geiger–Müller)
Ionising radiation events as countable pulses.
|
0–10 mSv/h | 1 count | ±15 % | Seconds to average | Pulse / interrupt | Scrap-metal monitoring, NDT sources and educational labs. Count with an interrupt, not polling, or you lose events. |
|
Infrared flame detector
The flicker signature of a flame in the near infrared.
|
760–1100 nm | Alarm point | Detection within 3 s | <3 s | Digital or analog | Fast, but sunlight and halogen lamps can fool it. Pair it with smoke detection and require both before a suppression action. |
Position & presence
14 entriesDistance, presence, orientation, rotation, magnetic fields and motion.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Passive infrared motion
Movement of warm bodies across a segmented infrared field of view.
|
3–7 m, 120° cone | Zone-based | Detection only | ≈1 s | Digital | Fine for 'did someone move', poor for 'is someone still here'. Warm air currents, sunlight and pets cause false triggers. |
|
24 GHz mmWave presence
Presence and micro-movement from reflected radar, including breathing.
|
0.1–8 m | Millimetre displacement | ±0.1 m ranging | 0.1 s | UART | Detects a still person where PIR fails. It sees through plastic and plasterboard, but not metal. Tune the gate and sensitivity for the room. |
|
Ultrasonic distance
Distance from the time of flight of a sound pulse.
|
2 cm–4 m | 3 mm | ±1 % | 20–50 Hz | Trigger/echo or I²C | Tanks, bins, sumps and robot bumpers. The speed of sound changes with temperature, so compensate or accept a slow drift. |
|
Time-of-flight laser
Distance from the flight time of a modulated light pulse.
|
4–8 m | 1 mm | ±1 % | Up to 60 Hz | I²C | Precise level and position. Glass, black rubber and very shiny surfaces return poor echoes; test the actual target. |
|
Infrared proximity
Short-range presence from reflected infrared.
|
2–150 cm | 1 cm | ±10 % | 100 Hz | I²C | Cheap and fast for hand detection and bin fill. Ambient sunlight is the enemy; choose a modulated type with ambient rejection. |
|
Reed / magnetic contact
Open or closed state of a door, gate, lid or panel.
|
Binary | State | Contact rating dependent | <1 ms | Digital, normally-closed preferred | Wire normally-closed so a cut cable looks like an alarm, not a safe door. Add a second contact for tamper. |
|
Hall magnetic field
Magnetic flux density: position, rotation or current indirectly.
|
±300 mT | 12-bit | ±1 % | 1 kHz | Analog or I²C | Non-contact RPM, end-stops and magnet position. Keep the magnet gap inside the specified window and expect temperature drift. |
|
Tilt / ball switch
Orientation past a fixed angle, or a lid being lifted.
|
Typical 10–45° trip | Binary | Angle tolerance ±5° | <10 ms | Digital | Tip-over protection, lid tamper and float. Debounce mechanically; a ball switch chatters at the threshold. |
|
3-axis accelerometer
Acceleration, vibration and shock on three axes.
|
±2 to ±16 g | 0.06 mg/LSB at ±2 g | ±1 % | 1 kHz+ | I²C or SPI | A machine-health front end when sampled fast and analysed in the frequency domain. For bearing faults, mount it rigidly on the housing, not on a bracket. |
|
3-axis gyroscope
Angular rate around three axes.
|
±125 to ±2000 °/s | 0.007 °/s | ±2 % | 1 kHz | SPI or I²C | Rotation, steering and motion compensation. It drifts; fuse it with an accelerometer or magnetometer for a stable angle. |
|
3-axis magnetometer
The local magnetic field: compass heading, vehicle presence or tamper.
|
±1300 µT | 0.3 µT | ±1° after calibration | 100 Hz | I²C | Calibrate hard and soft iron offsets in place. Steel structures and motors distort the field far more than you expect. |
|
Quadrature rotary encoder
Rotation angle and direction from two phase-shifted pulses.
|
20–1024 counts/revolution | 0.09° mechanical | Count-exact | Up to 100 kHz edges | Interrupts / quadrature decoder | The correct knob for a control panel: endless, detented and readable. Debounce in hardware and decode in an interrupt. |
|
Dual-axis joystick
X/Y position from two potentiometers or Hall sensors.
|
±30° travel | 10-bit | ±1 % | 100 Hz | Analog | Camera control, manual jog and menus. Add a centre dead-zone and a spring-return check at boot. |
|
Linear potentiometer / fader
Linear position as a voltage divider.
|
10 kΩ, 10–100 mm travel | 0.1 mm | ±2 % | Analog, 100 Hz | Analog | Faders, damper position and manual setpoints. Wear at the wiper shows up as noise; filter and replace on schedule. |
Force & vibration
5 entriesWeight, strain, impact and the vibration signature of a machine that is wearing out.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Load cell + 24-bit ADC
Weight or force from a strain-gauge bridge.
|
0–50 kg (cell dependent) | 0.1 g | ±0.02 % FS | 10–80 Hz | Bridge + 24-bit ADC | Tanks, parts counting, door weight and feed hoppers. Mount so load passes through the cell axis; side load is the usual cause of drift. |
|
Strain gauge
Microstrain in a structure or machine frame.
|
±2000 µε | 1 µε | ±1 % | 1 kHz | Bridge + 24-bit ADC | Structural monitoring and overload detection. Temperature compensation and a stable bridge excitation matter more than ADC bits. |
|
Force-sensitive resistor
Contact force from a change in resistance.
|
0.1–10 N | Logarithmic | ±10 % | 100 Hz | Analog | Touch, seat occupancy and grip. Repeatability is poor; use it for presence of force, not for measurement. |
|
Piezo vibration / shock
Vibration and impact from a piezoelectric element.
|
0.1–10 kHz | Relative | ±10 % relative | Microseconds | Analog + threshold | Impact detection and bearing knock. The signal is high-impedance: buffer it close to the sensor and clamp the input. |
|
Capacitive touch
A finger or hand near an electrode.
|
0–10 mm through glass or plastic | 8-bit proximity | ±1 mm with tuning | 50 Hz | Digital | Sealed panels with no moving parts. A film of water can look like a touch, so guard-ring the electrode and require a deliberate gesture. |
Electrical
7 entriesCurrent, voltage, energy, contactor feedback and battery state.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Current transformer clamp
AC current in a conductor from the induced secondary current.
|
0–100 A AC | 0.1 A | ±1 % | 50/60 Hz cycles | Analog (burden resistor) | Split-core clamps retrofit without cutting the cable. Clamp one conductor only; clamping the whole cable reads zero. |
|
Hall current sensor
DC or AC current from the magnetic field around a conductor.
|
±30 A | 10 mA | ±1 % | 100 kHz | Analog | Solar strings, batteries and DC pumps. Zero-offset drift is the main error; take a no-load reading at boot. |
|
Isolated voltage sense
Mains or DC bus presence and magnitude.
|
0–250 V AC/DC | 0.1 V | ±1 % | 1 kHz | Isolated analog | Mains-present, generator and UPS status. Isolation is not optional: use a certified divider or transformer, never a bare resistor chain. |
|
Energy / power meter
Active power and cumulative energy per circuit.
|
0–100 A | 0.1 % active energy | ±0.5 % | 1 Hz | SPI or UART | Allocates kWh to circuits and proves savings. Calibrate the voltage and current channels against a reference meter. |
|
Contactor feedback
Whether a relay or contactor actually closed, not just whether it was commanded.
|
Binary | State | Contact dependent | <10 ms | Digital, opto-isolated | The difference between a command and a fact. Use an auxiliary contact and alarm when the two disagree for more than a second. |
|
UPS dry contact
On-battery, low-battery and fault state from a UPS.
|
Binary set | State | Per UPS | <100 ms | Opto-isolated digital | Treat as an input, never as a source of truth for runtime. The UPS may lie about charge; measure the load and the battery separately. |
|
Battery voltage / current
Terminal voltage and charge/discharge current of a battery bank.
|
0–60 V, ±50 A | 1 mV, 10 mA | ±0.5 % | 10 Hz | I²C | 12/24/48 V banks and solar. Voltage alone is a poor state-of-charge estimate under load; count coulombs as well. |
Level & proximity
5 entriesTank level, float state, and industrial proximity and beam detection.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Float switch
A liquid reaching a fixed height.
|
Binary | Float travel | ±5 mm | <100 ms | Digital | Use two: one to start and stop the pump, one as an independent overflow alarm. Never rely on a single float for a safety function. |
|
Capacitive proximity
Non-metallic objects or liquid through a wall.
|
1–25 mm | Binary | ±10 % | 100 Hz | Digital | Detects product through a plastic tank wall. Humidity and build-up shift the threshold; teach it with the tank empty and full. |
|
Inductive proximity
Metal objects without contact.
|
2–15 mm | Binary | ±5 % | 1 kHz | Digital | End-stops, RPM and metal part counting. The sensing distance is quoted for mild steel; aluminium and stainless need a correction factor. |
|
Photoelectric beam
An object interrupting a light beam over a long distance.
|
0.1–30 m | Beam width | Detection only | <1 ms | Digital | Perimeter, conveyor counting and safety curtains. Align it, shade it from sunlight, and add a test input so a broken beam fails safe. |
|
Radar level
Liquid or solid level from the flight time of a radar pulse.
|
0.1–15 m | 1 mm | ±2 mm | 1 Hz | UART | Tanks with foam, vapour or dust. It struggles with low-dielectric media; check the dielectric constant before promising accuracy. |
Identity & biometric
5 entriesRFID, keys, keypads, fingerprints and vital-sign front ends.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
RFID / NFC reader
A tag identity and, where supported, a secure memory sector.
|
4–10 cm | Tag UID | Read reliability >99 % | ≈100 ms | SPI / UART | Access, tool tracking and consumable spools. A UID is an identifier, not a secret; use authenticated sectors for access decisions. |
|
Fingerprint
A fingerprint image reduced to a template.
|
500 dpi | Template match | FAR ≈0.1 % | <1 s | UART | Store templates, never images. Add a PIN or card as a second factor for anything that matters. |
|
Matrix / capacitive keypad
Key presses on a 12- or 16-key pad.
|
12–16 keys | Key event | With debounce | 50 Hz | Digital matrix | PIN entry and setpoints. Scan with a matrix and debounce; a capacitive pad needs a deliberate-press rule to reject water films. |
|
PPG heart rate / SpO₂
Pulse and blood-oxygen estimate from light absorption.
|
30–240 bpm | 1 bpm | ±2 bpm | 25 Hz | I²C | Presence and wellness, not diagnosis. Motion and ambient light destroy the signal; shield the sensor and reject bad frames. |
|
Single-lead ECG front end
The electrical activity of the heart.
|
0.5–40 Hz | 24-bit | Diagnostic-grade front end | 250 Hz | Analog + ADC | Requires proper electrode placement, isolation and a medical-grade supply. This is a demonstration front end, not a medical device. |
Weather
4 entriesRain, wind, solar irradiance and lightning near the site.
| Principle | Range | Resolution | Accuracy | Response | Interface | Notes |
|---|---|---|---|---|---|---|
|
Tipping-bucket rain gauge
Rainfall from counted bucket tips.
|
0.2 mm per tip | 0.2 mm | ±2 % | Per tip | Pulse / interrupt | Skip irrigation after real rain and watch roof drainage. Debounce the reed; wind makes it chatter. |
|
Wind vane
Wind direction from a coded vane.
|
0–360°, 16 points | 1° | ±5° | 1 Hz | Analog or Gray code | Combine with an anemometer for a wind vector. Mount it clear of the roof edge or it measures the building, not the wind. |
|
Lightning detector
The radio signature of lightning and its approximate distance.
|
1–40 km | ≈1 km | ±20 % | Event | I²C | Storm shutdown for outdoor equipment and irrigation. Treat distance as an estimate and add a margin. |
|
Solar irradiance
Broadband solar power per square metre.
|
0–1500 W/m² | 1 W/m² | ±5 % | 1 Hz | Analog | Solar yield, greenhouse shading and irrigation demand. Keep the dome clean; a dirty dome silently reads low. |
How these become a system
A sensor is one input to a loop: condition the signal, decide with a rule you can read, act through a relay or a display, then keep a record. The job sheets show the loop for twelve real problems.