Panels that feel like equipment.

A faceplate with real switches, a knob with a detent, a display you can read across the room, and an E-stop that cuts the coil. Built for gloved hands, bad light and the person on shift at 3 a.m.

14 control types9 readout options Hard-wired safety chainInteractive demo below
Try it

The demo panel is real logic.

Every control below changes a state that runs through the same rules an Arduino would execute. Press the E-stop and watch the outputs drop, the display latch and the logic trace say why.

Plant room 01 · control
PLANT ROOM 01STANDBY
22.4 °C
SETPOINT 23.0 · NO PUMPS
FLOW0.0 L/M
DOORSEALED
MODE STANDBY SAFETY OK LINK LOCAL
OUT 1
PUMP 1
OUT 2
PUMP 2
OUT 3
VALVE
OUT 4
ALARM
Main / key
E-stop
Pump 1
Pump 2
Setpoint
Door contact
Acknowledge
Main arms the panel · E-stop latches a safe state · ACK clears it only when the condition is gone

Logic trace

boot: rules loaded, outputs off

What the controller is doing

  • Reading the setpoint knob and the door contact every 100 ms
  • Comparing temperature against setpoint with a 1 °C dead band
  • Driving the pump relays and reading their feedback
  • Latching the E-stop and refusing to restart without ACK
Controls

Fourteen ways to mean something.

The control is a sentence: what it does, how long it lasts and what happens if you let go.

Momentary pushbutton

A action that only exists while pressed: start, jog, acknowledge, test.

Maintained switch

A state that stays put: auto/manual, heat/cool, enable/disable.

Selector switch

Two to four labelled positions with a positive detent and a visible pointer.

Key switch

Physical authority: run, program and lockout positions that need a key, not a menu.

Mushroom E-stop

Normally-closed, latching, hard-wired in series with the contactor coil — never through software alone.

Toggle / rocker

Fast local isolation for a single actuator, with a guard where accidental operation matters.

Rotary encoder

Endless, detented navigation and value entry with acceleration for big ranges.

Potentiometer / fader

Direct analogue setpoint with a physical position you can read at a glance.

Joystick

Two-axis manual jog for cameras, gantries and test rigs, with a centre dead-zone.

Lever / paddle

A positive mechanical action for valves, dampers and conveyors, with a position switch.

Foot pedal

Hands-free cycle control where both hands stay on the work.

Membrane keypad

A sealed, wipe-clean numeric entry surface for wash-down and food areas.

Capacitive touch

A sealed panel with no moving parts; needs a deliberate-press rule and water rejection.

Magnetic key

A non-contact key for a cover or a maintenance hatch, with no exposed contacts.

Readouts

The value has to be readable from where the person stands.

A display is chosen by viewing distance, light and consequence — not by the number of colours it can show.

16×2 character LCD

The default when the value matters and the budget is real. Readable in daylight, needs a backlight at night.

20×4 character LCD

More labels without a graphics stack; good for a plant room with eight values.

128×64 graphic LCD

Simple icons, bar graphs and two-level menus on a monochrome panel.

128×64 OLED

High contrast and wide viewing angle, best indoors; burn-in is real on static content.

Colour TFT

Trends, gauges and a touch surface when the panel is also the interface.

Seven-segment LED

A number at ten metres. Nothing beats it for a single value in a bright room.

Bar graph / LED ladder

Instant at-a-glance level, load or temperature without reading a number.

RGB status beacon

One colour per state, with a shape and a label so colour is never the only signal.

E-ink

A last-known value that survives a power cut and costs nothing to hold.

Panel rules

Eight rules that keep a panel honest.

None of these are about taste. Each one prevents a specific failure.

Fail safe by wiring

The E-stop and the safety chain interrupt the contactor coil directly. Software observes and reports; it does not grant permission.

Debounce in hardware and software

A 100 nF capacitor and a 20 ms software rule. A bouncing button is a random number generator.

Hysteresis on every threshold

A fan that starts at 30 °C stops at 28 °C. Otherwise it chatters at the setpoint all night.

Read back every output

An auxiliary contact proves the contactor closed. A command is not a fact.

Label the consequence

Not 'AUTO' but 'AUTO — starts on high level'. The panel should teach the operator.

One colour per meaning

Green run, amber warn, red stop, blue remote. Never reuse a colour for two meanings.

Guard the accidental

A flip guard over a red switch, a two-second hold on a destructive action, a key for programming.

Keep the seams serviceable

Terminals, fuses and a wiring schedule inside the door. The next person is you in two years.

Panel types

Built for a job, not for a photo.

Machine jog panel

Momentary start, maintained auto/manual, a guarded jog button, an E-stop and a four-line display for position, speed and fault. The operator never needs a menu to stop the machine.

Plant room panel

Pump 1/2/auto selectors, a keyed run/program switch, flow and pressure on a character LCD, a seven-segment temperature and a beacon. One glance from the doorway.

Test bench console

Encoder navigation, a colour TFT for the trend, a fader for manual setpoint, banana jacks for the device under test and an isolated USB link. Everything the technician touches is on the faceplate.

Lighting / effects console

Faders with physical positions, bump buttons, a scene keypad and a master blackout. The state is visible without a screen, which is the point of a console.

Signal handling inside the panel

Debounce. A button is a mechanical switch that bounces for 5–20 ms. A 100 nF capacitor and a 20 ms software rule turn it into one event. Without both, a single press can start a pump three times.

Matrix scanning. A 4×4 keypad needs eight lines, not sixteen. Scan columns, read rows, and never block the loop while waiting for a key.

Interrupts for motion. Encoders, flow pulses and RPM inputs are counted in an interrupt and converted outside it. Polling loses counts at speed.

Analogue filtering. A median-of-five plus a slow exponential average removes mains hum and wiper noise without adding visible lag to a setpoint.

Hysteresis. Every threshold has two values: the point that starts an action and the point that stops it. A single threshold chatters.

Output read-back. The auxiliary contact and the current clamp tell you what actually happened. A panel that only knows what it commanded is guessing.

FACE LAYOUT
PLANT ROOM 01
INLET22.4 °C
SET23.0 °C

Readout top, controls bottom, safety within reach. Nothing important needs a submenu.

Your panel

What should the operator be able to do without thinking?

Tell me the machine, the sequence, the failure that must be stoppable and the environment. I will specify the controls, the readouts and the safety chain.